Server Room in a Box

Both the APC Netshelter CX and Liebert MCR offers a server room in a box which allows for immediate IT deployment wherever and whenever it is needed, saving, space, cost and deployment time. No need to build dedicated IT space. Simply roll in the enclosure, rack your IT gear and “plug and play”.

What’s Included?

Sealed Enclosure
UPS
Power Distribution
Cable Management
Temperature Monitoring

Nuts & Bolts

SPS provides a fully assembled and tested “plug and play” server room in a box

1IndentifyThe Perfect Fit
Point of Sale Small Retail, Board Room A/V Media
12U 2 mid-sized servers with networking hardware
SMB Small Medium Business, Banking Branch, Remote Office
18U 4 mid-sized servers with networking hardware
SMB Small Medium Business, Manufacturing
24U 6 mid-sized servers with networking hardware
School Districts, Universities, Municipalities
38U 8 mid-sized servers with networking hardware
School Districts, Universities, Municipalities
44U 8 mid-sized servers with networking hardware
2Review Technical Requirements

If your space is too small for your Server Room in a Box, SPS has your back. Choose one of our Contracting Services and we will work with your building manager to accomodate your server space needs.

Model SPSBX12U SPSBX18U SPSBX24U SPSBX38U SPSBX44U
Rack Capacity 12U 18U 24U 38U 44U
Integrated PDU (3) 5-15 (13) 5-15 (12) 5-15 (11) 5-15 (10) 5-15
Netshelter CX AR4000MV AR4018 AR4024 AR4038 MCR
Network Management Card AP9631 AP9631 AP9631 AP9631 IS-WEBCARD
Max thermal load 0.8kW 2730BTU 1.8kW 4100BTU 2.4kW 8200BTU 3.6kW 12,300BTU 3.2kW 10,935BTU
Dimensions (H x W x D) 27.56 x 27.17 x 36.1 40.4 x 30 x 44 50.6 x 30 x 44 77 x 30 x 44 78 x 19 x 38
Max ambient temp 75F 75F 75F 75F 105F
Input Outlet Required 5-15 5-15 5-20 L5-30 (1) L5-30 (1) 5-15
Cable Manager AR8602 AR8602 AR8602 AR8602
Patch Panel AR8452 AR8452 AR8452 AR8452
Backup Cooling Module BCM2000 Low Noise
Liebert MCR HD788CC00KA3097
Cooling System ECM2000
Additional Items Front/Rear Square Hole Plexi Door with ECM Vent BCM Systems Side Panels w/Insulation Castors High Temp Alarm Extension Duct 38" ECM Heat Rej. Fan 60Hz
ECM, 3YR Extended Warr. 3WEECM
BCM, 3YR Extended Warr. 3WEBCM
Warranty Inspection S10186A-ECM
APC SmartUPS X LCD SMX3000RMLV2U
Liebert GXT4 GXT4-3000RT120
3Select Your UPS Options
APC SMX750 SMX1500RM2U SMX2200RM2U SMX3000RM2U SMX3000RM2U
Liebert GTX4-700RT120 GXT4-1500RT120 GXT4-2000RT120 GXT4-3000RT120 GXT4-3000RT120
4That’s It! Just Request Quote To Complete…
Yes… I’ve reviewed the above specifications and requirements.