securepwr.com (215)804.1186
APC Smart UPS Products Part Number
120V Output / 120V Input
APC Smart-UPS 750VA USB & Serial 120V SUA750
APC Smart-UPS 750VA USB & Serial RM 1U 120V SUA750RM1U
APC Smart-UPS 750VA USB & Serial RM 2U 120V SUA750RM2U
APC Smart-UPS 1000VA USB & Serial 120V SUA1000
APC Smart-UPS 1000VA USB & Serial RM 1U 120V SUA1000RM1U
APC Smart-UPS 1000VA USB & Serial RM 2U 120V SUA1000RM2U
APC Smart-UPS 1500VA USB & Serial 120V SUA1500
APC Smart-UPS 1500VA USB & Serial RM 2U 120V SUA1500RM2U
APC Smart-UPS 2200VA USB & Serial 120V SUA2200
APC Smart-UPS 2200VA USB & Serial RM 2U 120V SUA2200RM2U
APC Smart-UPS 3000VA 120V SU3000NET
APC Smart-UPS 3000VA RM 5U 120V SU3000RMNET
APC Smart-UPS 3000VA USB & Serial 120V SUA3000
APC Smart-UPS 3000VA USB & Serial RM 2U 120V SUA3000RM2U
120V, 208V Output / 208V Input
APC Smart-UPS 5000VA RM 7U w/Transformer 208V in and 120/208V out, black, L5-20R Receptacles SU5000R5T-TF3
APC Smart-UPS 5000VA RM 7U w/Transformer 208V In 208/120V Out, Black SU5000R5TBXFMR
APC Smart-UPS 5000VA RM 7U w/Transformer 208V In 208/120V Out SU5000RMT5UXFMR
APC Smart-UPS 5000VA w/Transformer 208V In 208/120V Out SU5000TXFMR
208V Output / 208V Input
APC Smart-UPS 3000VA 208V SU3000TNET
APC Smart-UPS 3000VA USB & Serial RM 2U 208V SUA3000RMT2U
APC Smart-UPS 5000VA RM 5U 208V Black SU5000R5TBX120
APC Smart-UPS 5000VA RM 5U 208V SU5000RMT5U
APC Smart-UPS 5000VA 208V SU5000T

APC Smart UPS Features & Benefits
Availability
Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances.
Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to actual battery temperature.
Intelligent battery management Provides higher availability through intelligent precision-charging that maximizes battery performance, life, and reliability.
Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power.
Automatic self-test Ensures early detection of potential problems by periodic testing of UPS components.
Boost and Trim Automatic Voltage Regulation (AVR) Preserves battery life and maximizes run time by correcting low and high voltage conditions without discharging the battery.
Cold-start capable Provides temporary battery power when the utility power is out.
Generator compatible Ensures clean, uninterrupted power to protected equipment when generator power is used.
Manageability
SmartSlot Customize UPS capabilities with management cards.
Audible alarms Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.
LED status indicators Quickly understand UPS status with indicators.
Network manageable Provides remote management of the UPS over the network.
Serial Connectivity Provides management of the UPS via a serial port.
Serviceability
Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment throughout battery replacement.
Predictive failure notification Provides early-warning fault analysis ensuring proactive component replacement.
Resettable circuit breakers Enables quick recovery from UPS overload events.
Adapatability
Adjustable voltage-transfer points Saves battery power and helps extend battery life.
Adjustable voltage sensitivity Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Safety
Safety-agency approved Ensures product testing and approval to work safely with the connected loads and within the environment.