| Smart UPS RT Product |
Part Number |
| 120V Output / 120V Input |
| APC Smart-UPS RT 1500VA RM 120V |
SURTA1500RMXL |
| APC SMART-UPS RT 1500VA 120V |
SURTA1500XL |
| APC Smart-UPS RT 2000VA RM 120V |
SURTA2000RMXL |
| APC SMART-UPS RT 2000VA 120V |
SURTA2000XL |
| APC Smart-UPS RT 3000VA RM 120V |
SURTA3000RMXL |
| APC SMART-UPS RT 3000VA 120V |
SURTA3000XL |
| 120V, 208V Output / 208V Input |
| APC Smart-UPS RT 3000VA RM 208V w/ 208V to 120V
2U Step-Down Transformer |
SURT3000RMXLT-1TF5 |
| APC Smart-UPS RT 3000VA 208V w/ 208V to 120V Step-Down
Transformer |
SURT3000XLT-1TF3 |
| APC Smart-UPS RT 5000VA RM 208V w/ 208V to 120V
2U Step-Down Transformer |
SURT5000RMXLT-1TF5 |
| APC Smart-UPS RT 5000VA 208V w/ 208V to 120V Step-Down
Transformer |
SURT5000XLT-1TF3 |
| APC Smart-UPS RT 7500VA RM 208V w/ 208V to 120V
2U Step-Down Transformer |
SURT7500RMXLT-1TF5 |
| APC Smart-UPS RT 7500VA 208V w/ 208V to 120V Step-Down
Transformer |
SURT7500XLT-1TF3 |
| APC Smart-UPS RT 10,000VA RM 208V w/ (2) 208V to
120V 2U Step-Down Transformer |
SURT10000RMXLT-2TF5 |
| APC Smart-UPS RT 10,000VA 208V w/ (2) 208V to 120V
Step-Down Transformer |
SURT10000XLT-2TF3 |
| 208V Output / 208V Input |
| APC Smart-UPS RT 3000VA RM 208V |
SURT3000RMXLT |
| APC Smart-UPS RT 3000VA 208V |
SURT3000XLT |
| APC Smart-UPS RT 5000VA RM 208V |
SURT5000RMXLT |
| APC Smart-UPS RT 5000VA 208V |
SURT5000XLT |
| APC Smart-UPS RT 7500VA RM 208V |
SURT7500RMXLT |
| APC Smart-UPS RT 7500VA 208V |
SURT7500XLT |
| APC Smart-UPS RT 10,000VA RM 208V |
SURT10000RMXLT |
| APC Smart-UPS RT 10000VA 208V |
SURT10000XLT |
| Smart UPS RT Features & Benefits |
| Availability |
| Automatic internal bypass |
Supplies utility power to the connected loads in
the event of a UPS overload condition or fault. |
| Scalable runtime |
Allows quick addition of more runtime when needed. |
| Intelligent battery management |
Provides higher availability through intelligent
precision-charging that maximizes battery performance, life, and
reliability. |
| Hot-swappable batteries |
Ensures clean, uninterrupted power to protected
equipment throughout battery replacement. |
| Automatic restart of loads after UPS shutdown |
Automatically starts up the connected equipment
upon the return of utility power. |
| Manageability |
| InfraStruXure Manager compatible |
Enables centralized management via APC's InfraStruXure
Manager. |
| Network manageable |
Provides remote management of the UPS over the network. |
| SmartSlot |
Customize UPS capabilities with management cards. |
| LED status indicators |
Quickly understand UPS status with indicators. |
| Serial Connectivity |
Provides management of the UPS via a serial port. |
| Adaptability |
| Plug-and-Play external batteries |
Ensures clean, uninterrupted power to the loads
when adding extra runtime to the UPS. |
| Rack/Tower convertible |
Protects the initial investment in the UPS when
migrating from tower to rack-mount environment. |
| Flash-upgradeable firmware |
Easy implementation of new firmware upgrades. |
| Serviceability |
| User-replaceable batteries |
Enables simple upgrades and replacement of the Batteries. |
| Automatic self-test |
Ensures early detection of potential problems by
periodic testing of UPS components. |
| Predictive failure notification |
Provides early-warning fault analysis ensuring proactive
component replacement. |
| Disconnected battery notification |
Warns when a battery is not available to provide
backup power. |
| Audible alarms |
Actively let you know if the unit is on battery,
if the battery is low or if there is an overload condition. |
| Protection |
| Frequency and voltage regulation |
Preserves battery life and maximizes runtime by
correcting poor frequency and voltage conditions without discharging
the battery. |
| Power conditioning |
Protects connected loads from surges, spikes, lightning,
and other power disturbances. |
| Input power factor correction |
Minimizes installation costs by enabling the use
of smaller generators and cabling. |
| Generator compatible |
Ensures clean, uninterrupted power to the loads
in the event of an extended power outage |
| Cold-start capable |
Provides temporary battery power when the utility
power is out. |
| Resettable circuit breakers |
Enables quick recovery from UPS overload events. |
| Safety-agency approved |
Ensures product testing and approval to work safely
with the connected loads and within the environment. |