securepwr.com (215)804.1186
Smart UPS RT Product Part Number
120V Output / 120V Input
APC Smart-UPS RT 1500VA RM 120V SURTA1500RMXL
APC SMART-UPS RT 1500VA 120V SURTA1500XL
APC Smart-UPS RT 2000VA RM 120V SURTA2000RMXL
APC SMART-UPS RT 2000VA 120V SURTA2000XL
APC Smart-UPS RT 3000VA RM 120V SURTA3000RMXL
APC SMART-UPS RT 3000VA 120V SURTA3000XL
120V, 208V Output / 208V Input
APC Smart-UPS RT 3000VA RM 208V w/ 208V to 120V 2U Step-Down Transformer SURT3000RMXLT-1TF5
APC Smart-UPS RT 3000VA 208V w/ 208V to 120V Step-Down Transformer SURT3000XLT-1TF3
APC Smart-UPS RT 5000VA RM 208V w/ 208V to 120V 2U Step-Down Transformer SURT5000RMXLT-1TF5
APC Smart-UPS RT 5000VA 208V w/ 208V to 120V Step-Down Transformer SURT5000XLT-1TF3
APC Smart-UPS RT 7500VA RM 208V w/ 208V to 120V 2U Step-Down Transformer SURT7500RMXLT-1TF5
APC Smart-UPS RT 7500VA 208V w/ 208V to 120V Step-Down Transformer SURT7500XLT-1TF3
APC Smart-UPS RT 10,000VA RM 208V w/ (2) 208V to 120V 2U Step-Down Transformer SURT10000RMXLT-2TF5
APC Smart-UPS RT 10,000VA 208V w/ (2) 208V to 120V Step-Down Transformer SURT10000XLT-2TF3
208V Output / 208V Input
APC Smart-UPS RT 3000VA RM 208V SURT3000RMXLT
APC Smart-UPS RT 3000VA 208V SURT3000XLT
APC Smart-UPS RT 5000VA RM 208V SURT5000RMXLT
APC Smart-UPS RT 5000VA 208V SURT5000XLT
APC Smart-UPS RT 7500VA RM 208V SURT7500RMXLT
APC Smart-UPS RT 7500VA 208V SURT7500XLT
APC Smart-UPS RT 10,000VA RM 208V SURT10000RMXLT
APC Smart-UPS RT 10000VA 208V SURT10000XLT

Smart UPS RT Features & Benefits
Availability
Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS overload condition or fault.
Scalable runtime Allows quick addition of more runtime when needed.
Intelligent battery management Provides higher availability through intelligent precision-charging that maximizes battery performance, life, and reliability.
Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment throughout battery replacement.
Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power.
Manageability
InfraStruXure Manager compatible Enables centralized management via APC's InfraStruXure Manager.
Network manageable Provides remote management of the UPS over the network.
SmartSlot Customize UPS capabilities with management cards.
LED status indicators Quickly understand UPS status with indicators.
Serial Connectivity Provides management of the UPS via a serial port.
Adaptability
Plug-and-Play external batteries Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
Rack/Tower convertible Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
Flash-upgradeable firmware Easy implementation of new firmware upgrades.
Serviceability
User-replaceable batteries Enables simple upgrades and replacement of the Batteries.
Automatic self-test Ensures early detection of potential problems by periodic testing of UPS components.
Predictive failure notification Provides early-warning fault analysis ensuring proactive component replacement.
Disconnected battery notification Warns when a battery is not available to provide backup power.
Audible alarms Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.
Protection
Frequency and voltage regulation Preserves battery life and maximizes runtime by correcting poor frequency and voltage conditions without discharging the battery.
Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances.
Input power factor correction Minimizes installation costs by enabling the use of smaller generators and cabling.
Generator compatible Ensures clean, uninterrupted power to the loads in the event of an extended power outage
Cold-start capable Provides temporary battery power when the utility power is out.
Resettable circuit breakers Enables quick recovery from UPS overload events.
Safety-agency approved Ensures product testing and approval to work safely with the connected loads and within the environment.