| ISX Power Distribution Products |
| 208V 3PH Input |
Part Number |
| InfraStruXure
PDU 40kW 208V/208V W/ MBP |
PD40F6FK1-M |
| InfraStruXure
PDU 60kW 208V/208V |
PD60F6FK1 |
| InfraStruXure
PDU 80kW 208V/208V W/ MBP |
PD80F6FK1-M |
| Rack
Distribution Panel 208 V |
PDRDPF10U-R |
| InfraStruXure
PDU 60kW 208V/208V Xmerless |
PDRPPNX10 |
| InfraStruXure
PDU 40kW 208V/208V W/ MBP Xmerless |
PDRPPNX10-M |
| InfraStruXure
PDU 80kW 208V/208V W/ MBP Xmerless |
PDRPPNX14-M |
| 480V 3PH Input |
Part Number |
| InfraStruXure
PDU 150kW 480V/208V |
PD150G6F |
| InfraStruXure
PDU 40kW 480V/208V W/ MBP |
PD40G6FK1-M |
| InfraStruXure
PDU 60kW 480V/208V |
PD60G6FK1 |
| InfraStruXure
PDU 80kW 480V/208V W/ MBP |
PD80G6FK1-M |
| ISX Power Distribution Features & Benefits |
| Economy |
| Smallest footprint |
Minimizes your real estate expenses |
| Circuit Breaker Panel |
Provides breaker positions for distribution to
racks and power zones |
| System mobility |
Configurable with an input pin connector eliminating
the need for a hardwire input connection |
| Availability |
| Transformer for Step-down or Step-up or Isolation |
Step down transformer placed upstream of the UPS
to avoid inrush current and saturation eliminating need to oversize
transformer |
| Load Test Port |
Load test port provides simple connection for full
testing of a Symmetra PX UPS |
| Alarm Thresholds |
Current Transformers on each circuit that can provide
amp ratings on each circuit position to prevent circuit breaker
overloads |
| Wide Range of Applications |
Configure-to-order process allows APC to configure,
install, and test complete system before shipping |
| Manageability |
| Local and web-based monitoring |
Status available to customers both in the data
center and remotely |
| Serviceability |
| Front-access servicing |
No side access required |
| ISX Power Distribution |
 |
 |
| ISX PDU Models |
| Nominal Input Voltage |
Model |
Part Number |
| 120V |
Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA
5-20R |
AP7830 |
| Rack PDU, Metered, Zero U, 15A, 100/120V, (16) 5-15 |
AP7831 |
| Rack PDU, Metered, Zero U, 30A, 120V, (24) 5-20 |
AP7832 |
| 208V |
Rack PDU, Metered, Zero U, 20A, 208V, (6) L6-20 |
AP7622 |
| Rack PDU, Metered, Zero U, 20A, 200/208V, (20)C13 & (4)C19 |
AP7840 |
| Rack PDU, Metered, Zero U, 30A, 200/208V, (20)C13 & (4)C19 |
AP7841 |
| 208V 3PH |
Rack PDU,Metered,2U,5.7kW,120&208V,(3)L5-20 & (3)L6-20 |
AP7610 |
| Rack PDU, Metered, Zero U, 5.7kW, 120V, (42)5-20 |
AP7862 |
| RackPDU,Metered,ZeroU,5.7kW,120/208V,(21)5-20&(6)L6-20 |
AP7863 |
| Rack PDU,Metered, ZeroU, 5.7kW, 208V, (36)C13 & (6)C19 |
AP7864 |
| Rack PDU,Metered,ZeroU,12.5kW,208V,(30)C13,(6)C19;3'
Cord |
AP7868 |
| Rack PDU,Metered,ZeroU,5.7kW,120V,(42)5-20; 10'
Cord |
AP7892 |
| RackPDU, Metered, ZeroU, 5.7kW, 120 & 208V,
(21)5-20 & (6)L6-20; 10' Cord |
AP7893 |
| Rack PDU,Metered, ZeroU,5.7kW,208V,(36)C13&(6)C19;
10' Cord |
AP7894 |
| Rack PDU,Metered,ZeroU,12.5kW,208V,(30)C13,(6)C19;10'
Cord |
AP7898 |
| 230V |
Rack PDU, Metered, Zero U, 10A, 230V, (16) C13 |
AP7850 |
| ISX PDU Features and Benefits |
| Availability |
| Local Current Monitoring Display |
The aggregate current draw per power
distribution unit is displayed on the unit via a digital display.
The local digital display helps installers avoid overloaded circuits
by providing a visible warning when the current draw is close to
the maximum amperage draw of the strip. |
| Alarm Thresholds |
Define alarm thresholds in order to
avoid overloaded circuits. Network and visual alarms inform the
user of possible problems. |
| Network Management |
Full-featured network management interfaces
that provide standards-based management via Web, SNMP, and Telnet.
Allows users to access, configure, and manage units from remote
locations to save valuable time. Associated with this feature is
the ability to quickly and easily upgrade the firmware via network
download to installed units for future product enhancements. (Note:
Only applicable for units categorized as Networked). |
| InfraStruXure Manager compatible |
Enables centralized management via
APC's InfraStruXure Manager. |
| Load Indicator LED |
Indicates overload and warning conditions
based on the user-defined alarm thresholds. Alerts users of potential
overloaded circuits. |
| Agility |
| Rack-Mountable |
Includes horizontal, vertical, and
toolless-mount varieties. Puts power where it is needed most -
in the racks near the equipment. |
| Single input power source |
Supply power from one branch whip to
multiple pieces of equipment, conveniently powering rack-mount
equipment. Saves time and money during installation by using one
branch whip and standard connections. |
| Wide range of input and output connections |
Product family includes a variety of
input and output connections to distribute 120V, 208V, or 230V
power to multiple outlets. Having a variety of inputs and outputs
allow users to adapt to varying power requirements. APC offers
units that bring up to 12.5kW using a single branch whip. |
|